DENON RD-500 Specifications |
American Standard |
Metric Standard |
Zoom Lens Magnification (15" monitor) |
126X |
126X |
Top Heater Wattage (Hot Air/Gas) |
700 Watts |
700 Watts |
Bottom Localized Heater Wattage (Hot Air/Gas) |
700 Watts |
700 Watts |
Area Array Heater Wattage - Dark IR |
2400 Watts |
2400 Watts |
Temperature Setting Range (Top Heater) |
0 - 1202° F |
0 - 650 ° C |
Temperature Setting Range (Bottom Heater) |
0 - 1202° F |
0 - 650 ° C |
Temperature Setting Range (Area Array Heaters) |
0 - 1202° F |
0 - 650 ° C |
Air Requirements - Dry / Clean Air
(4 SCFM Intermittent, Estimate at 50% duty) |
44.99 PSIG |
0.1 - 1.0 MPA |
Nitrogen Requirements - Dry / Clean Nitrogen
(Requires 1.5 SCFM intermittent) |
44.99 PSIG |
0.1 - 1.O MPA |
Electrical Power Requirements 200-230 VAC to Ground / Neutral |
200- 230 VAC |
200- 230 VAC |
Three (3) Wire Power Cable (Black/Black/Green) Supplied with six (6') cable |
Neutral / Ground / Hot
50 / 60 HZ, 1 Phase |
Neutral / Ground / Hot
50 / 60 HZ, 1 Phase |
Required Circuit Amperage - Dedicated Line
(Fused Neutral 15 AMP / Hot 15 AMP) |
20 AMPS |
20 AMPS |
Receptacle Requirements Type |
NEMA L6-30-R/30A/250V
|
NEMA L6-30-R/30A/250V
|
| Receptacles Total (3) |
1-NEMA, 2-STD/120V |
1-NEMA, 2-120V
Local Plug Type |
Maximum Load Capacity
(Bench Requirements) |
~ 200 Lbs |
~ 90 Kgs |
| Working Space Requirements |
|
|
REAR Side of Machine
( Service Access) |
1' |
304.8 mm |
Machine Installation Suggested Location |
Well Lighted and Well Ventilated |
Well Lighted and Well Ventilated |
Air Inlet Size and Fitting Type
(Located in Machine Rear /Single Filter Regulation) |
0.25" OD
Legris Type |
|
Air Inlet Tubing Size
(Located in Machine Rear /Single Filter Regulation) |
*0.236” OD
|
*6mm OD
|
Exhaust Requirements
Ventilation Flow (25CFM ) |
0.25" CFM |
6.4 mm |
Machine Height Adjustment Range
(Foot Pads are 1" in Diameter) |
1" |
25 mm |
Power Requirements
PC Controller |
120 VAC |
120 VAC |
Power Requirements
Video Display |
120 VAC |
120 VAC |